1. Power Supply:
AC Input Supply : 220 V AC, 50Hz
DC Input Supply : 24 V DC

2. Operating Conditions : -10 to 45 C, 95 % RH Max.

3. Operating Voltage : 24 V DC

4. Normal Loop Voltage : 20.7 DC

5. Open Threshold Current : 4.2 mA

6. Short Circuit Threshold Current : 40 mA

7. Stand by Threshold Current : 8.2 mA
( EOL Current + detector's Current)

8. Alarm Current : 20 - 35 mA

9. Quiescent Current : 60mA

10. Colour of the Panel : Broken White (Red, Red Texure - Optional)

11. Panel Size : 350 X 250 X 100(Width X Height X Depth)

12. Approximate Weight : 4Kgs.

13. ALARM OUTPUT: Common Hooter Output : 24V@1A.

14. REMOTE OUTPUTS:
Output : Fire, Fault Relay Contacts (30V AC/ DC @ 2A contact).

Additional Information:
  • Item Code: Re-102
  • Minimum Order Quantity: 1 Piece(s)
  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: chennai
  • Production Capacity: 3
  • Delivery Time: 7 days from the date of receipt of firm PO
Yes! I am interested
Get CALLBACK

4 Zone Fire Alarm Panel

4 Zone Fire Alarm Panel
 
Get Best Quote
Approx. Rs 7,400 / Piece(s)Get Latest Price

Features
  • As per IS -15908: 2011 Standard.
  • 16 X 2 Dot Matrix LCD Display.
  • Standby battery backup with built in charging.
  • Fire / Fault status in unambiguous colored LED indication.
  • Switch Mode Power Supply.
  • Tactile Keypad for easy panel operation.
  • System on indication.
  • Main, Standby status indication.
  • Low Battery visual warning with audible tone.
  • Relay output for actuators for Fire and Fault.
  • Lamp Test facility
  • Zone wise one man walk Test Facility.
  • Zone wise Isolation facility with loop voltage cut off.
  • Compatible to all type of Conventional Detectors.
  • Optional Zone Wise Sounder / Zone Wise Contact.
Electrical Specification
Primary Power
120 – 220VAC , 50 Hz
Common Relays
Type : Form C
No of Relays : 3
Relay Contact Rating : 2Amps @ 30 VDC, 0.5Amps @125VAC.
Power Factor : 1
Standby Power
24V D.C (2 Nos of 12v, 7Ah Sealed Lead acid battery).
Quiescent current : 55mA
Operating Condition
Operating Temperature : 0 – 49° C/32-120° F.
Relative Humidity : 93 ± 2% RH (non- condensing) at 32 ±2° C/90 ±3° F.
Initiating Device Circuits (Zone Circuit)
All zones are Class B wiring
Normal Operating Voltage : 14- 21 VDC
Alarm Current : 15 – 30mA
Short Circuit Current : 42mA Maximum
Loop resistance : 50 ohms Maximum
End-Of-Line Resistor : 4.7K, 1/4watt
Standby Current : 6.8mA (2.4mA for Detectors)
Charging Circuit
Charging Voltage 28.2V, ±0.5V
Charging Current 0.5 A (Max.).
Notification Appliance Circuits
Class B wiring
Operating Nominal Voltage : 24VDC
Current for NACs : 0.6 Amp
End-Of-Line Resistor : 4K7, 1/4 watt

Additional Information:
  • Item Code: RE-104
  • Minimum Order Quantity: 1 Piece(s)
  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: chennai
  • Production Capacity: 3
  • Delivery Time: 7 days from the date of receipt of firm PO
Yes! I am interested
View PDF
Explore More Products
X
Looking for “Fire Alarm Panel”?
Find Us D. Sujatha (Business Development Head) Plot No. 295, Burma Colony, 4th Main Road Perungudi, Chennai - 600096, Tamil Nadu, India
SEND SMS
SEND E-MAIL
Share Us: